Bitzer Ecolite A2L Condensing Unit LHL5E/4EES-4Y c/w OLC-K1 low level oil switch 4HP

Product code: BZCU28-203
Manufacturer code LHL5E/4EES-4Y
PLEASE LOGIN TO SEE PRICES
Product Group : SPECIALS CAPITAL EQUIPMENT
General
Product Group : SPECIALS CAPITAL EQUIPMENT
Additional Info
Family : Ecolite
HP Control Device Provided : Yes
Liquid Line Provided : Yes
Suction Valve Provided : Yes
Application
Application : LBP/MBP/Fridge.Freezer
Compressor
Compressor Model : 4EES-4
Displacement : 22.7 m³/h
Number Of Compressors : 1
Number Of Phases (Compressor) : 3
Power Supply Compressor : 400/3/50 V/Ph/Hz
Connections
Liquid Line Connection : 5/8 in, 16 mm
Suction Line Connection : 1 1/8 in, 28 mm
Electrical
LRA : 53.5 A
MCC : 12.2 A
Power Supply : 400/3/50 V/Ph/Hz
RLA : 12.8 A
Fan
Fan Blade Size : 450 mm
Fan Diameter : 450 mm
Fan Size : 450 mm
Number Of Fans : 2
Power Supply Fan : 230/1/50 V/Ph/Hz
General Information
Model Number : LHL5E-4EES-4Y
Receiver Volume : 15 L
Measurements
Height : 1230 mm
Length : 450 mm
Net Weight : 210 kg
Weight : 210 kg
Width : 1300 mm
R404A Performances
R404A Capacity -5°C : 14020 W
R448A/R449A Performances
R448A/449A Capacity -5°C : 13230 W
R448A/449A Capacity -25°C : 5290 W
R448A/R449A Cooling Capacity -10°C : 11442 W
R448A/R449A Cooling Capacity -25°C : 5749 W
R448A/R449A Cooling Capacity -35°C : 2963 W
R513A Performances
R513A Cooling Capacity Rated -10°C : 7560 W
R513A Cooling Capacity Rated 0°C : 11339 W
R513A Cooling Capacity Rated 5°C : 13611 W
Refrigerant
GWP : 631
Refrigerant : R134a, R407A, R407C, R407F, R448A, R449A, R450A, R454C, R455A, R513A, R1234yf
Sound Power/Pressure
Sound Pressure Level 50 Hz 10m : 42.5 dB(A)
Product information
ECOLITE is a fully equipped "plug and play" air-cooled unit for indoor or outdoor installation, made for DX applications. Capacity control (10-100% LHL5; 50-100% LHL3) provides smooth and energy efficient operation even with large load variations. The same model can be used for both refrigeration and freezing applications.
A1 refrigerants: R448A, R449A, R450A, R513A, R134a, R407A, R407C, R407F.
A2L refrigerants (GWP<150) that can be used: R1234yf, R1234ze, R454C, R455A.
EN 378 and the Swedish Cooling Standard provide good guidance for safe installation and operation.
File name Extension Size
Brochures pdf 969.47 KB
Product Number Manufacturer product number Technical data Price Availability
BBK0967-CRO
Container Pack Condensing Unit
Available after log in
Available after log in
LHL5E/4CES-6Y
Bitzer Ecolite A2L Condensing Unit LHL5E/4CES-6Y c/w OLC-K1 low level oil switch 6HP
Available after log in
Available after log in
LHL5E/4DES-5Y
Bitzer Ecolite A2L Condensing Unit LHL5E/4DES-5Y c/w OLC-K1 low level oil switch 5HP
Available after log in
Available after log in
LHL5E/4EES-4Y
Bitzer Ecolite A2L Condensing Unit LHL5E/4EES-4Y c/w OLC-K1 low level oil switch 4HP
Available after log in
Available after log in
LHL5E/4FES-3Y
Bitzer Ecolite A2L Condensing Unit LHL5E/4FES-3Y c/w OLC-K1 low level oil switch 3HP
Available after log in
Available after log in